Status |
ExpNbr |
Date |
Author |
Type |
Category |
Target-Source |
Subject |
Fixed | e768s |
Fri Jul 19 00:03:25 2019 |
Jenn | BEAM | General | | Brho information 15 Oxygen beam 4.7MeV/u |
|
Fixed | e768s |
Fri Jul 19 00:06:35 2019 |
Jenn | BEAM | General | | Brho information 15 Oxygen beam 4.7MeV/u |
|
Fixed | e768s |
Fri Jul 19 03:29:58 2019 |
Jenn | ONLINE | General | LiF | Screenshots run 112 overnight |
MUGAST and VAMOS screenshots run 112 |
Fixed | e768s |
Mon Jul 29 01:27:59 2019 |
Jenn | BEAM | General | LiF | Beam intensity and profile check |
Run number 156: 15-O beam
beam intensity 8.8e6
OR Vamos ~ 106 |
Fixed | e768s |
Mon Jul 15 18:05:14 2019 |
Iulian, Serge | RUN | General | N/A | Run7 - TAC calibration |
*************************
Run : 7
*************************
Start at 2019-07-15 18:04:51.105052
TAC Time calibrator
range 2.56 um
period 20ns
TACs range settings:
1. VAMOS - AGATA -> 500 ns
2. FAG - HF -> 200 ns
3. CATAS1 - HF -> 500 ns
4. VAMOS - HF -> 2 us
5. MUGAST - VAMOS -> 2 us
6. MUST2 - AGATA -> 2 us
7. MUST2 - HF -> 2 us
8. BAF2 - HF -> 1 us
9. AGATA - HF -> 200 ns
Stop at 2019-07-15 18:16:11.458928
Stop comment: Finish 1st time calibration. Changing ranges now |
Fixed | e768s |
Mon Jul 15 18:17:49 2019 |
Iulian, Serge | RUN | General | N/A | Run8 - TAC calibrations |
*************************
Run : 8
*************************
Start at 2019-07-15 18:17:21.942994
TAC Time calibrator
range 2.56 um
10 ns period |
Fixed | e768s |
Mon Jul 15 18:39:03 2019 |
Iulian, Serge | RUN | General | N/A | Run9 - TAC calibration |
*************************
Run : 9
*************************
Start at 2019-07-15 18:38:59.133455
TAC Time calibrator
range 2.56 um
10 ns period
Stop at 2019-07-15 19:04:03.255467
Stop comment: type your message here
Stop at 2019-07-15 19:18:09.593144
Stop comment: end of tac time calibration |
Fixed | com2019 |
Sat Apr 6 02:48:39 2019 |
Iulian Ruxandra | RUN | Software | | Online Spectra run 256 @2h30 am 06/04 (for reference) |
The online spectra (for reference)
No timing on Mg3 & Mg4 side X. Those correspond with the masked channels on the Muvi1 |
Fixed | com2019 |
Sat Apr 6 02:52:51 2019 |
Iulian Ruxandra | RUN | Software | | Online Scalers run 256 @2h30 am 06/04 for reference |
|
Fixed | com2019 |
Sat Apr 6 03:22:30 2019 |
Iulian Ruxandra | RUN | Software | | New Kinematics plots (4h of stats) |
More statistics on the script written by Adrian and Valerian (first image)
Second image is a comparison between the excited states produced between 90-130 deg and 130-180 deg. Effects of angular distribution?
the kinematic line seen in the Elab vs Theta at backward angles can be observed in figure 3. Are those protons? |
Fixed | e744s |
Sun Apr 14 03:30:28 2019 |
Iulian Iulia | OFFLINE | Social | CH2 | first calculation ECM ThetaCM for gamma-P emission |
|
Fixed | e744s |
Thu Apr 11 19:19:21 2019 |
Iulian Beyhan | RUN | General | N/A | Change target CH2 to no target |
Target hole is now removed -> No target |
Fixed | e744s |
Sun Apr 14 16:55:57 2019 |
Iulian Antoine | VAMOS | Hardware | CH2 | rTarget change and Brho change VAMOS before run 125 for off resonance measurement |
16:30 start run 124
setting brho for next run
brho old = 0.519964
finger old = +12 mm
brho new = 0.550875
finger new = +16 mm
16:55 start run 125 with thinner CH2 target #5 for off-resonance measurement |
Fixed | e744s |
Sat Apr 13 12:39:02 2019 |
Iulian ->Jaromir update | ONLINE | Hardware | N/A | Scalers - U2M23 must be the finger |
Looks like U2M_23 is in fact the beam dump (plastic finger).
This day scalers were looked at;
Tested OR_VAMOS + U2M23 = CATS2
the discrepancy is on level of 1-2% for the actual rate,
or approx 500-1000cps for TOTALS of the scalers. |
Fixed | TEST |
Fri Mar 29 10:00:52 2019 |
Iulian | VAMOS | General | N/A | GMT channel4 corresponds to VAMOS now |
Voie4 GMT = trigger Vamos |
Fixed | e744s |
Sat Apr 13 10:32:59 2019 |
Iulian | ONLINE | General | CH2 | Screenshots run 122 v3 |
Is missing the scalers |
Fixed | com2019 |
Tue Apr 2 14:46:27 2019 |
Iulian | OTHER | Hardware | N/A | TACs calibration |
TACs calibrations have been performed:
TAC offset slope
T_Cats1_2 | 0. | 0.0250725 |
T_Si_Cats1 | 0. | 0.0246678 |
T_Si_Vamos | 0. | 0.0253243 |
T_Si_Agata | 0. | 0.0251722 |
T_Vamos_Cats1 | 0. | 0.0255071 |
T_Cats1_HF | 0. | 0.0111935 |
T_Fag_HF | 0. | 0.0104992 |
T_Vamos_Agata | 0. | 0.0252933
|
|
Fixed | e744s |
Wed Apr 10 20:16:22 2019 |
Iulian | BEAM | General | N/A | 14N beam characteristics and Brho vamos setting |
Also the beam profile on gas profiler before and after inserting a peperpot |
Fixed | e744s |
Sun Apr 14 18:38:53 2019 |
Giuseppe, Mariluz, Jenn; Serge, Nishu, Didier, Simon | ONLINE | General | CH2 | Log & Scalers -- Run 125 at 18:40 |
|
Fixed | e744s |
Sun Apr 14 20:23:50 2019 |
Giuseppe, Mariluz, Jenn, Serge, Nishu, Didier, Simon | ONLINE | General | CH2 | Log & Scalers -- Run 125 at 20:20 |
|