Fixed, , Fri Feb 15 15:31:28 2019, Marlène, GRIT, General, N/A, Detectors bias 
, e775s, Fri Feb 28 13:58:31 2020, Marlène, , , ,  
Fixed, e768s, Sat Jul 20 19:21:56 2019, Marlene, Nicolas, Christian, Fairouz, OFFLINE, General, , Trying to understand AGATA g-ray yields 
goal: we want to check whether the yields of the 1297.7 keV (from 19Ne 1536, 3/2+, l=1 state) and 1340 keV (from 19Ne 1615, 3/2-, l=2 state) g-ray lines is compatible with what we expect from x-sec calculations

conditions: we consider runs 112, 115 and 116

observations:
N(1297) = 17 g-rays
N(1340) = 23 g-rays

remarks:
Given x-sec from mirror nucleus (Francois 15N(7Limt) paper) we expect N(1340) >~ N(1297)

ingredients:
1. beam normalization
We use the TAC_FPMW_HF as a proxy. During the same time we integrate the prompt peak and compare the integrated OR VAMOS scaler, we find Scaler(OR VAMOS)/N(TAC) = 193.
We use the comparison of the OR VAMOS (pps) and the beam profiler (pps), we find profiler/OR VAMOS = 1e4
We obtain (2.17e5 + 6.44e4 + 3.52e5)*193*1e4 = 1.2 e12 15O incident particles (at profiler position!)

2. target thickness -> known to be 1.25 mg/cm2 of LiF (RBS measurement)
N(Li) = 1.25e-3 / (19+7) * 6.02e23 at/cm2

3.efficiencies
AGATA @ 1.3 MeV -> 7.5 %
VAMOS intrinsic -> 67 % (Eff_Check.C macro applied to run 116)
MUGAST -> 50 % (lab, geometry), needed because MUGAST is the main trigger

4. 19Ne charge state
we assume 40 % for 9+

5. g-ray branching ratio -> taken from NNDC

6. cross-section
we calculate differential cross section for the 1536-keV 19Ne state (FRESCO, FR-DWBA)
-> at 0 deg, ds/dW =
-> integrated x-sec in VAMOS acceptance (4 deg (lab) -> 20 deg (cm)) = 445 micro barn (C2Sa = 1)
-> taking into account know spectroscopic factor form analog state -> 89 micro barn

Conclusion:
for the 1536-keV 19Ne state we obtain 30 g-rays, instead of 17.

Discussion:
This factor of two could be well within the mirror symmetry assumption. However it seems it is also the case for the 1615-keV 19Ne state, so would not it be a systematic error with a factor of two missing somewhere (beam transmission between the profiler and the target? deficiencies?)?
Fixed, com2019, Sat Apr 6 12:38:17 2019, Marlene et Valerian, RUN, General, CD2, Tac Si Vamos with gate on GATCONFMASTER > 8 T_Si_Vamos_GATCONF_inf_8.png
Fixed, , Tue Apr 9 21:47:20 2019, Marlene Valerian, GRIT, General, , FSC time calibration 9th april evening FSC_calib_09042019.png
Snapshot of FSC calibration just before experiment

The noisy MG detectors are still there but otherwise most of them are OK
Fixed, , Thu Feb 14 15:30:14 2019, Marlene Daniele Jenny, GRIT, General, 3-alpha, RUN 28 3alpha_sourceMG03XY._OKpng3alpha_sourceMG11XY.png3alpha_sourceMG01XY_OK.png
RUN 28 14th Feb
3 alpha source on MG11A, MG3T, MG1T

GMT channels
MG11
-
MG3
-
-
MG1
-
Fixed, , Thu Feb 14 08:50:58 2019, Marlene, GRIT, General, 3-alpha, RUN 27 8x
RUN 27 on 14th of feb.
3 alpha source (one in front of trap., one in front of square detectors)

MG10, MG4, MG7 and MG5 are OK.
MG1 shows alpha but at lower energy and with bad resolution (particularly on X). We suspect it is not well depleted. We tried to increase the bias up to 200V but did not see any change.
It is due to a non working SA/SL external cable that produces this error (we tested it with several detectors, we also tried to change the MUVI channel and it still does the same)

Conclusion :
We have tested all trapezoid detectors (MG1, MG3, MG4, MG5, MG7) the annular (MG11) and the thin square (MG10) they are all OK




Detectors (order in the GMT) :
MG10
MG1
MG4
-
MG7
MG5
-
-

attached : bias of detectors ( be careful : MG10 bias = MG11A)
spectra for all detectors
Fixed, com2019, Mon Feb 18 10:41:36 2019, Marlene, GRIT, General, N/A, Bias & current of detectors bias.png
Fixed, , Mon Mar 4 17:22:29 2019, Marlene, GRIT, General, , Temperature on MUFEE MUST2 13deg 8x
Temperature given by DAS on MUVI3 (MUST2)
screenshots before run
after run : same values
Fixed, TEST, Thu Mar 7 09:29:47 2019, Marlene, GRIT, General, , run 96 double alpha source run shifted 60mm  run96_MG7_MG11notworking.pngrun96_3alphasource_shifted_MG1-5.pngrun96_HV2.pngrun96_HV1.png
RUN 96

double alpha source
MG1
MG3
MG4
MG5

MG7
-
-
MG11

MM1
MM2
MM3
MM4

Missing strips in Y the same as in run 40

Problem with the annular MG11 -> no current when bias is put... --> to be checked

Problem with the insertion of the target holder --> solved

I also checked again MG9 (still noisy)
and MG10 with 140V I=0,52uA and counting rate is the same order of magnitude as trapezoid. Spectra are OK (not saved).
Fixed, TEST, Sun Feb 23 22:17:49 2020, Marlene, RUN, Hardware, , tracetek error 
When filling the coolers with alcohol the tracetek cable triggered and switched off water and supplies.
Beam is off
Fixed, e744s, Sat Apr 13 15:25:56 2019, Marion, Kseniia, Dieter, Didier, Guiseppe, IuliaH, Catalin, ONLINE, General, CH2, Scalers v8 for run122.1 run122_1_scalers_v8.png
"1_" added to screenshot filenames to indicate automatic file opening
Fixed, e744s, Sat Apr 13 15:31:32 2019, Marion, Kseniia, Dieter, Didier, Guiseppe, IuliaH, Catalin, ONLINE, Social, CH2, Screenshots run 122.1 v6 20x
"1_" added to screenshot filenames to indicate automatic file opening
Fixed, e744s, Sat Apr 13 11:42:16 2019, Marion, Kseniia, Dieter, Didier, Guiseppe, IuliaH, ONLINE, Social, CH2, Screenshots - spectra zeroed after previous screenshot taking 20x
spectra zeroed after previous screenshot taking
Fixed, e744s, Sat Apr 13 11:44:21 2019, Marion, Kseniia, Dieter, Didier, Guiseppe, IuliaH, BEAM, General, CH2, tempory beam interruption 
ventilation problem SPIRAL& - beam stopped for presumably appro. 10 min (PCP info)

beam is back at 11:52 h
Fixed, e744s, Sat Apr 13 12:32:03 2019, Marion, Kseniia, Dieter, Didier, Guiseppe, IuliaH, ONLINE, General, CH2, Scalers run122_scalers_v5.png
Fixed, e744s, Sat Apr 13 13:13:18 2019, Marion, Kseniia, Dieter, Didier, Guiseppe, IuliaH, ONLINE, Social, CH2, Screenshots run 122 v5 20x
Fixed, e744s, Sat Apr 13 13:42:22 2019, Marion, Kseniia, Dieter, Didier, Guiseppe, IuliaH, RUN, General, CH2, New run 122...1 generated after 4G on disk 
Fixed, e744s, Sat Apr 13 13:58:08 2019, Marion, Kseniia, Dieter, Didier, Guiseppe, IuliaH, BEAM, Hardware, CH2, beam rate (read from CATS) as a function of time rate_vs_time.pdf
Fixed, e744s, Sat Apr 13 14:19:41 2019, Marion, Kseniia, Dieter, Didier, Guiseppe, IuliaH, ONLINE, General, CH2, Scalers run122_scalers_v7.png