Fixede793s Thu Mar 11 03:37:45 2021 LouisOFFLINEGeneralCD2Offline analyis run 53
1) Some angular distribution were extracted (without any efficiency corrections) with gate on Ex btw 0 and 2 MeV (where p orbitals are populated) and btw 2 and 4 MeV (where f orbitals are populated). More counts are observed btw 110 and 120 degrees in Lab angle with the 0-2MeV gate compared to the 2-4MeV gate which is expected from the AWBA calculus. Kinematic cuts the large angles at high excitation energies. Geometrical efficiency is needed to compare this angular range. Looks like we well distinguish L=1 and L=3 transfers.

2) Some gamma spectra obtained with Ex gate btw -1 and 1, 1 and 3, 3 and 5 MeV.

3) Some strange horizontal lines are observed in the E-TOF id in MUST2. The spectra was obtained with gate on the promt signal in vamos so it can not be the beam intercepting directly must2...

4) the Ex vs Eg matrix
Attachment 1: AngDistrib.png
AngDistrib.png
Attachment 2: Eg_Ex.png
Eg_Ex.png
Attachment 3: ETofMM.png
ETofMM.png
Attachment 4: ExEg.png
ExEg.png
Attachment 5: Ex_Theta.png
Ex_Theta.png
Fixede793s Thu Mar 11 02:50:14 2021 Ablaihan, LouisBEAMGeneralCD2VAMOS transmition
at 2h50 beam intensity reached 1.1x10^6 pps in CATS for 6.5x10^5 pps in VAMOS. The transmition decreased to 60% without any shift of the beam position. Does it come from a loss of efficiency of VAMOS at high counting rate?
Fixede793s Thu Mar 11 01:24:47 2021 Ablaihan, LouisRUNGeneralCD2run 53 screenshots
Screenshots of the run 53
Beam intensity is ~ 7.4 10^5 pps in CATS and 5.3 10^5 in VAMOS
~75% transmition
Dt is ~ 3%
Attachment 1: run53_Scalers.png
run53_Scalers.png
Attachment 2: run53_MM_Impact.png
run53_MM_Impact.png
Attachment 3: run53_Times.png
run53_Times.png
Attachment 4: run53_VAMOS_MWpng
Attachment 5: run53_MM_TY.png
run53_MM_TY.png
Attachment 6: run53_MM_TX.png
run53_MM_TX.png
Attachment 7: run53_MG_TY.png
run53_MG_TY.png
Attachment 8: run53_MG_TX.png
run53_MG_TX.png
Attachment 9: run53_MM_ErawY.png
run53_MM_ErawY.png
Attachment 10: run53_MM_ErawX.png
run53_MM_ErawX.png
Attachment 11: run53_MG_ErawY.png
run53_MG_ErawY.png
Attachment 12: run53_MG_ErawX.png
run53_MG_ErawX.png
Attachment 13: run53_MG_E_TOF.png
run53_MG_E_TOF.png
Attachment 14: run53_MM_dEE.png
run53_MM_dEE.png
Attachment 15: run53_MM_E_TOF.png
run53_MM_E_TOF.png
Attachment 16: run53_MG_impact.png
run53_MG_impact.png
Pendinge793s Wed Mar 10 23:37:23 2021 Nishu, Chloe, TarasRUNGeneral FAG value increased
Around 11:30 pm FAg value increased from usual 60-70 units to 140 units. It is suspected that MUGAST increased the trigger rate.
Attachment 1: FAG_value.png
FAG_value.png
Fixede793s Wed Mar 10 22:19:22 2021 Adrien, Freddy, Wilton and NigelOFFLINEGeneralCD2Offline analysis of run 51 and 52 using ganil files
We noted that the gamma ray efficiency calculated from file converted from AGATA was close 100%. We concluded that the conversion program was reauiring a gamma ray to be present.

This is confirm by analysis of the ganil dta file that show 10 time more count that the agata one.

Here is a kinematical plot of the run 51 and 52 analysised from ganil file.

There is a 1.5MeV state present that disappear in the agata coincidence. This is to be investigated with more data. Is it an isomer state? from 48K? 48Ti?
Attachment 1: RUN5152_ELabThethaLab.png
RUN5152_ELabThethaLab.png
Ongoinge793s Wed Mar 10 21:09:25 2021 mugast (Adrien, Nigel et co)BEAMGeneral Primary beam issues

The secondary beam intensity has been fluctuating around 4 - 5 x 10**5 Hz most of the evening. 15 mins ago it was realised that it had dropped off to only 1 x 10**5 Hz. As suspected, PCP confirmed that primary beam intensity has dropped off. They are investigating ...

It would be good to have the TI (primary beam intensity) available to monitor here in the daq room.
Fixede793s Wed Mar 10 21:02:03 2021 OttoRunRUNGeneralCD2Run53
*************************
Run : 53
*************************

Start at 2021-03-10 21:00:45.001418

Production run.

Beam: 4.5e5 pps
target: CD2 0.5mg
Trigger are MUGAST/MM/CATS%

Stop at 2021-03-11 09:40:34.970341
Stop comment: run stopped to enter and check position 0 ATC6 trip
Fixede793s Wed Mar 10 20:53:55 2021 OttoRunRUNGeneralCD2Run52
*************************
Run : 52
*************************

Start at 2021-03-10 18:16:20.382279

Beam in the room; restarting daq after changing trigger.
target: CD2 0.5mg
Trigger are MUGAST/MM
changed width of the FAG to 400ns
Removed extra 100ns delay from cats validation
Pendinge793s Wed Mar 10 20:36:19 2021 NigelBEAMGeneralCD2Beam centering - MUST2 hit pattern

We made a quick check of the beam centering by inspecting the MUST2 (forward angles) hit pattern (plot attached). It appears that the beam is probably somewhat off centre in the horizontal direction.

It has been decided to run overnight like this and then see with Bertrand if the centering can be improved (will need to send hit pattern spectrum to PCP in order for Bertam to do this).

Fixede793s Wed Mar 10 19:23:37 2021 mugastOFFLINEGeneralCD2Kinematics and Ex - RUN051
Preliminary analysis results, Backward angles.

MM5 position are incorrect
Attachment 1: RUN51_ELabThethaLab_Ex.png
RUN51_ELabThethaLab_Ex.png
Attachment 2: RUN51_ELabThethaLab_Ex_Egamma.png
RUN51_ELabThethaLab_Ex_Egamma.png
Fixede793s Wed Mar 10 18:22:01 2021 Taras, Nishu, ChloeRUNGeneral status screenshot
Fixede793s Wed Mar 10 17:25:22 2021 OttoRunRUNGeneralCD2Run51
*************************
Run : 51
*************************

Start at 2021-03-10 17:24:45.316220

Beam in the room; restarting daq after changing trigger.
target: CD2 0.5mg
Trigger are MUGAST/MM
changed width of the FAG to 400ns
Removed extra 100ns delay from cats validation

Stop at 2021-03-10 18:14:26.996869
Stop comment: stop for VAMOS data analysis. Coherence check

Stop at 2021-03-10 20:46:36.348405
Stop comment: stopped the run to add cats% in the trigger
Fixede793s Wed Mar 10 17:00:06 2021 OttoRunRUNGeneralCD2Run50
*************************
Run : 50
*************************

Start at 2021-03-10 16:59:44.368649

Beam in the room; restarting daq after changing trigger.
target: CD2 0.5mg
Trigger are MUGAST/MM
changing width of the FAG to 1us

Stop at 2021-03-10 17:12:21.612357
Stop comment: stopping to get in and change the cats delay
Fixede793s Wed Mar 10 16:31:50 2021 OttoRunRUNGeneralCD2Run49
*************************
Run : 49
*************************

Start at 2021-03-10 16:31:31.923710

Beam in the room; restarting daq after changing trigger.
target: CD2 0.5mg
Trigger are MUGAST/MM

Stop at 2021-03-10 16:53:12.237279
Stop comment: stopping to change GMT windows
Fixede793s Wed Mar 10 16:12:40 2021 OttoRunRUNGeneralEmptyRun48
*************************
Run : 48
*************************

Start at 2021-03-10 16:11:56.052849

Beam in the room; restarting daq after changing trigger.

Trigger are MUGAST/MM/CATS%

Stop at 2021-03-10 16:30:03.651340
Stop comment: stopping to remove cats% from trigger so we can set the timing
Fixede793s Wed Mar 10 16:07:43 2021 OttoRunRUNGeneralN/ARun47
*************************
Run : 47
*************************

Start at 2021-03-10 16:07:22.660368

Beam in the room; restarting daq after recompiling the action

Stop at 2021-03-10 16:09:55.182936
Stop comment: stopping run to remove vamos% from trigger
Fixede793s Wed Mar 10 15:15:44 2021 CharlieOTHERGeneral 48Ti Kinematics (additional)
Supplementary to Adrien's kinematic calculations of 47Ti(d,p)48Ti, we have found a paper suggesting that by far the most strongly populated state in 48Ti is at 5.65 MeV. There is also a doublet of strong states at around 4.4 MeV, and two more strongly populated states at 6.06 and 6.33 MeV.

See attachment for the full table from P. D. Barnes (1965), Phys.Rev.138.B597.

Some quick CatKin models also show that a (theoretical) state at 7 MeV in 48Ti would almost perfectly overlap with the ground state of 48K. As such, when looking at the lab energy with the g.s. of 48K normalised to 0, we could expect to see these strongly populated 48Ti states at -0.67, -0.94, -1.35 and -2.6 MeV (for 6.3, 6.06, 5.65 and 4.4 MeV, respectively).

See the attached plot for kinematics of 47K(d,p)48K @ 0 MeV and 4 MeV, as well as 47Ti(d,p)48Ti @ 0 MeV, 5.65 MeV and the theoretical 7 MeV. Additionally, see a mock-up of the expected spectra from Wilton.
Attachment 1: PDBarnes_Table_1.png
PDBarnes_Table_1.png
Attachment 2: 48Ti_and_48K_Kinematics.png
48Ti_and_48K_Kinematics.png
Attachment 3: Wilton_mock-up.png
Wilton_mock-up.png
Fixede793s Wed Mar 10 14:43:14 2021 OttoRunRUNGeneralN/ARun46
*************************
Run : 46
*************************

Start at 2021-03-10 14:42:50.365714

Test run for Professor Clement. Beam in the room.

Stop at 2021-03-10 16:02:30.981195
Stop comment:
Fixede793s Wed Mar 10 13:57:54 2021 OttoRunRUNGeneralN/ARun45
*************************
Run : 45
*************************

Start at 2021-03-10 13:57:50.701600

Agata or as trigger for testing before beam

Stop at 2021-03-10 14:01:53.157232
Stop comment:
Fixede793s Wed Mar 10 13:33:31 2021 OttoRunRUNGeneralN/ARun43
*************************
Run : 43
*************************

Start at 2021-03-10 13:33:01.346673

Agata or as trigger for testing before beam

Stop at 2021-03-10 13:55:37.322216
Stop comment: