Fixed, e768s, Mon Jul 15 14:29:47 2019, Marlène, MUST2, General, , Masks for MUST2 & Kapton changed for MG5 
|
Masks are now correctly mounted
All 4 kaptons from MG5 have been changed |
Fixed, e768s, Thu Jul 18 11:52:59 2019, Marlène, OTHER, Hardware, N/A, Division of SQUARE & MUST2
|
MUST2 DIV is now 10 (input 7 of GMT)
|
Fixed, e768s, Sun Jul 21 14:54:28 2019, Marlène, RUN, General, , run 119 scalers 
|
|
Fixed, e768s, Sun Jul 21 16:42:20 2019, Marlène, OFFLINE, General, , Conversion of data from AGATA :update
|
When VAMOS VXI crashed (run 118) the Action file was recompiled.
As AGATA conversion is not copying the ACTION file for each run, it used the old version by default (from 16th of july).
|
Fixed, e768s, Sun Jul 21 17:02:25 2019, Marlène, BEAM, General, , beam intensity in the afternoon
|
|
Fixed, e768s, Tue Jul 23 16:19:14 2019, Marlène, OTHER, Hardware, , VAMOS division
|
VAMOS division was set 10 instead of 100.
CATS 1 & CATS2 scalers are sent to the two last channels of the scaler |
Fixed, TEST, Wed Dec 4 19:19:38 2019, Marlène, GRIT, Hardware, , Modifications of set-up
|
We have installed the new MUFEE board in the reaction chamber for MG2. This board is a new version with ATHED.
We have moved the MG9 board to become the board to read the future MUST2 detector at 90 deg. This board is now perpendicular to the other ones. We have |
Pending, TEST, Tue Jan 21 17:55:12 2020, Marlène, MUST2, Hardware, , Ovv error on the -5V of CAEN boards   
|
The Ovv error shows on the -5V (first one) of the 3 board (5,3.3,10V for MUST2§squares)
It means that the voltage is over the asked value.
If we ask 5V, we get 5.5V in reality
|
Fixed, TEST, Wed Jan 22 15:53:25 2020, Marlène, GRIT, Hardware, , Changes for MUGAST2020
|
Changes were made for MUGAST 2020 :
1- the board for MG10 before (2nd square) is now for MG6 new trap
2- the board for MG9 is put vertical and used for the MUST2 at 90 deg
|
Fixed, TEST, Sun Feb 23 20:50:06 2020, Marlène, GRIT, General, , RUN 115 8x
|
Screenshots from MUGAST
The impact matrix looks fine but there are sectors missing but in the raw we see 13 sectors (instead of 16)
|
Fixed, TEST, Mon Feb 24 10:26:29 2020, Marlène, GRIT, General, , infos
|
We have changed the range of the TAC FAG-HF to 500ns (it was 200 ns before)
there is no delay on the STOP of MUVI, it is directly the HF clean.
|
Fixed, e775s, Wed Feb 26 15:02:38 2020, Marlène, RUN, General, , RUN 137 
|
RUN 137
CD2+Au #2
beam intensity 6e+5pps
|
Fixed, e775s, Wed Feb 26 15:12:02 2020, Marlène, RUN, General, , RUN 137 8x
|
Screenshots of RUN137
[quote="Marlène"]RUN 137
|
Fixed, e775s, Wed Feb 26 16:19:35 2020, Marlène, RUN, General, , RUN 137 (suite)
|
Here is the E gamma versus Excitation energy spectra for run 137
|
Fixed, , Thu Feb 27 15:56:09 2020, Marlène, RUN, General, , RUN 142 AGATA- 143 VAMOS-MUGAST
|
RUN142 on AGATA and RUN143 on MUGAST/VAMOS
target CD2 (350ug/cm2)
|
Fixed, , Thu Feb 27 16:25:45 2020, Marlène, RUN, General, , RUN 142-143 screenshots   
|
[quote="Marlène"]RUN142 on AGATA and RUN143 on MUGAST/VAMOS
target CD2 (350ug/cm2)
|
Fixed, , Thu Feb 27 16:30:53 2020, Marlène, RUN, General, , RUN 142 -143 preliminary analysis  
|
[quote="Marlène"][quote="Marlène"]RUN142 on AGATA and RUN143 on MUGAST/VAMOS
target CD2 (350ug/cm2)
|
Fixed, , Fri Feb 28 11:20:22 2020, Marlène, GRIT, General, , RUN 150
|
RUN 150
target CD2 300 ug/cm2
Beam intensity 4e+5pps
|
Fixed, e775s, Fri Feb 28 11:21:31 2020, Marlène, RUN, General, , RUN 151
|
RUN 151
Change of target now : CD2+AU #2
|
Fixed, e775s, Fri Feb 28 14:00:08 2020, Marlène, RUN, General, , RUN 151 beam stop
|
[quote="Marlène"]RUN 151
Change of target now : CD2+AU #2
|
|