Fixede768s Mon Jul 15 14:29:47 2019 MarlèneMUST2General Masks for MUST2 & Kapton changed for MG5Masks are now correctly mounted

All 4 kaptons from MG5 have been changed
 IMG_20190715_121646_crop_flip.jpgIMG_20190715_122035.jpg 
Fixede768s Thu Jul 18 11:52:59 2019 MarlèneOTHERHardwareN/ADivision of SQUARE & MUST2
MUST2 DIV is now 10 (input 7 of GMT)
  
Fixede768s Sun Jul 21 14:54:28 2019 MarlèneRUNGeneral run 119 scalers   run_119_scaler_beam2.pngrun_119_scaler_beam.png 
Fixede768s Sun Jul 21 16:42:20 2019 MarlèneOFFLINEGeneral Conversion of data from AGATA :updateWhen VAMOS VXI crashed (run 118) the Action
file was recompiled.
As AGATA conversion is not copying the ACTION
  
Fixede768s Sun Jul 21 17:02:25 2019 MarlèneBEAMGeneral beam intensity in the afternoon   run_119_scaler3.png 
Fixede768s Tue Jul 23 16:19:14 2019 MarlèneOTHERHardware VAMOS divisionVAMOS division was set 10 instead of 100.
CATS 1 & CATS2 scalers are sent to the two
last channels of the scaler
  
FixedTEST Wed Dec 4 19:19:38 2019 MarlèneGRITHardware Modifications of set-upWe have installed the new MUFEE board in the
reaction chamber for MG2. This board is a
new version with ATHED.
  
PendingTEST Tue Jan 21 17:55:12 2020 MarlèneMUST2Hardware Ovv error on the -5V of CAEN boardsThe Ovv error shows on the -5V (first one)
of the 3 board (5,3.3,10V for MUST2§squares)
It means that the voltage is over the asked
 BT_referenve_5V_cables_inv_a_comp_referenve_5V_partMUST2BT_referenve_5V_partMUST2_cables_inv_a_comp_referenve_5VBT_referenve_5V_partMUST2BT_referenve_5V 
FixedTEST Wed Jan 22 15:53:25 2020 MarlèneGRITHardware Changes for MUGAST2020Changes were made for MUGAST 2020 : 
1- the board for MG10 before (2nd square)
is now for MG6 new trap
  
FixedTEST Sun Feb 23 20:50:06 2020 MarlèneGRITGeneral RUN 115 Screenshots from MUGAST

The impact matrix looks fine but there are
 8x 
FixedTEST Mon Feb 24 10:26:29 2020 MarlèneGRITGeneral infosWe have changed the range of the TAC FAG-HF
to 500ns (it was 200 ns before)
  
Fixede775s Wed Feb 26 15:02:38 2020 MarlèneRUNGeneral RUN 137RUN 137
CD2+Au #2
beam intensity 6e+5pps
 Ex_137.pdfEx_run128_137.pdf 
Fixede775s Wed Feb 26 15:12:02 2020 MarlèneRUNGeneral RUN 137Screenshots of RUN137

[quote="Marlène"]RUN 137
 8x 
Fixede775s Wed Feb 26 16:19:35 2020 MarlèneRUNGeneral RUN 137 (suite)Here is the E gamma versus Excitation energy
spectra for run 137
 Ex_Egamma_run137.png 
Fixed  Thu Feb 27 15:56:09 2020 MarlèneRUNGeneral RUN 142 AGATA- 143 VAMOS-MUGASTRUN142 on AGATA and  RUN143 on MUGAST/VAMOS

target CD2 (350ug/cm2)
  
Fixed  Thu Feb 27 16:25:45 2020 MarlèneRUNGeneral RUN 142-143 screenshots[quote="Marlène"]RUN142 on AGATA and  RUN143
on MUGAST/VAMOS
 RUN143_ElabThetaLab.pngRUN143_impact.pngRUN143_tac.pngRUN143_tof.png 
Fixed  Thu Feb 27 16:30:53 2020 MarlèneRUNGeneral RUN 142 -143 preliminary analysis [quote="Marlène"][quote="Marlène"]RUN142 on
AGATA and  RUN143 on MUGAST/VAMOS
 RUN143_ana_Elab_Thetalab.pngRUN143_ana_Ex_Eg.pngRUN143_ana_Ex.png 
Fixed  Fri Feb 28 11:20:22 2020 MarlèneGRITGeneral RUN 150RUN 150
 target CD2 300 ug/cm2
Beam intensity 4e+5pps
  
Fixede775s Fri Feb 28 11:21:31 2020 MarlèneRUNGeneral RUN 151RUN 151

Change of target now : CD2+AU #2
  
Fixede775s Fri Feb 28 14:00:08 2020 MarlèneRUNGeneral RUN 151 beam stop[quote="Marlène"]RUN 151

Change of target now : CD2+AU #2
  