Fixed, e768s, Thu Jul 25 13:39:42 2019, mugast, BEAM, General, LiF, Beam stop due to high temperature
|
A lot of Qpoles power supplies had to be shutdown.
Beam stopped at 13h30. |
Fixed, e768s, Thu Jul 25 17:19:52 2019, Freddy, OFFLINE, General, N/A, Scaler evolution + scaler file reader
|
Attached is a plot of several scaler (frequency as a function of time) for all data from run 120 to 140.
A software was written to process the scaler.dat files and is located in:
|
Fixed, e768s, Thu Jul 25 22:39:36 2019, OttoRun, RUN, General, LiF, Run142
|
*************************
[SIZE=3][B]Run : 142[/B][/SIZE]
*************************
|
Fixed, e768s, Thu Jul 25 22:41:45 2019, OttoRun, RUN, General, LiF, Run141
|
*************************
[SIZE=3][B]Run : 141[/B][/SIZE]
*************************
|
Fixed, e768s, Fri Jul 26 00:02:49 2019, OttoRun, RUN, General, LiF, Run145
|
*************************
[SIZE=3][B]Run : 145[/B][/SIZE]
*************************
|
Fixed, e768s, Fri Jul 26 01:10:40 2019, OttoRun, RUN, General, LiF, Run146
|
*************************
[SIZE=3][B]Run : 146[/B][/SIZE]
*************************
|
Fixed, e768s, Fri Jul 26 01:47:44 2019, OttoRun, RUN, General, LiF, Run147
|
*************************
[SIZE=3][B]Run : 147[/B][/SIZE]
*************************
|
Fixed, e768s, Fri Jul 26 01:54:56 2019, OttoRun, RUN, General, LiF, Run148
|
*************************
[SIZE=3][B]Run : 148[/B][/SIZE]
*************************
|
Fixed, e768s, Fri Jul 26 02:27:48 2019, Marlène, Faïrouz, Franck, Bertrand, Sylvain, Diego, Nicolas, BEAM, General, , G1 profiler efficiency
|
G1 profiler efficiency was checked against CATS1 for two beam intensities. Agreement between the two measurements is within 20%
Profiler -> CATS1
|
Fixed, e768s, Fri Jul 26 02:33:22 2019, OttoRun, RUN, General, LiF, Run149
|
*************************
[SIZE=3][B]Run : 149[/B][/SIZE]
*************************
|
Fixed, e768s, Fri Jul 26 03:59:11 2019, Kseniia, Franck, ONLINE, General, LiF, Run 149 screenshots 17x
|
|
Fixed, e768s, Fri Jul 26 05:57:04 2019, Kseniia, Franck, ONLINE, General, LiF, Run 149 screenshots 17x
|
A second beam component is visible in particular in IC energy losses (with Z larger than 7) and in MW.
This probably corresponds to the 15O from the Spiral target-ion source being warmed up by the primary beam that has increased overnight (~1200 W at 5:45
am).
|
Fixed, e768s, Fri Jul 26 08:56:50 2019, Kseniia, AGATA, General, LiF, 135-149 run Gamma analysis 
|
19F Q8 charge state identified in VAMOS
Still no clear peak at 3908 keV... |
Fixed, e768s, Fri Jul 26 11:21:19 2019, OttoRun, RUN, General, LiF, Run150
|
*************************
[SIZE=3][B]Run : 150[/B][/SIZE]
*************************
|
Pending, , Fri Jul 26 11:25:46 2019, UK refugees, OTHER, General, , Be positive and the experiment will work if we put lead in our pencil
|
|
Fixed, e768s, Fri Jul 26 12:21:50 2019, OttoRun, RUN, General, LiF, Run151
|
*************************
[SIZE=3][B]Run : 151[/B][/SIZE]
*************************
|
Fixed, e768s, Fri Jul 26 13:48:41 2019, Marlène, Faïrouz, Bertrand & Nicolas, BEAM, General, , G1 profiler & VAMOS efficiency
|
Factor of two between the profiler and VAMOS FP determination of incident beam is now understood.
Several effects were at work simultaneously and checked at 2 beam intensities (9e3 pps and 5e4 pps):
|
Fixed, e768s, Fri Jul 26 14:06:33 2019, mugast, ONLINE, General, LiF, Screenshots run 151_1 20x
|
|
Fixed, e768s, Fri Jul 26 15:33:49 2019, OttoRun, RUN, General, LiF, Run152
|
*************************
[SIZE=3][B]Run : 152[/B][/SIZE]
*************************
|
Fixed, e768s, Fri Jul 26 15:48:12 2019, Kseniia, AGATA, General, , Full stats with AGATA on 19F with the 15N beam   
|
Charge state 8 (plus zooms) and charge state 7;
Statistics of all the 15N runs combined;
Identification in VAMOS;
|
|