Fixed, e768s, Mon Jul 22 05:19:36 2019, Faïrouz & Sylvain, RUN, General, LiF, Start new run 122 Beam-profile-run121-04h51.jpg
Start new run 122. AGATA validation was recovered.

BUT the AGATA request rate is increasing very quickly!!! The OR-AGATA increased up to ~32000. 
Fixed, e768s, Mon Jul 22 05:30:37 2019, Faïrouz & Sylvain, RUN, General, LiF, CF put because AGATA went crazy 
CF put because AGATA went crazy. 
The beam profile is shifted in comparison to the initial profile at midnight. The beam is touching somewhere. 
We asked the beam operators to try to center the beam. 
Fixed, e768s, Mon Jul 22 06:14:38 2019, Faïrouz & Sylvain, RUN, General, LiF, Run 122 with more centered beam profile Beam-profile-run122-06h13.jpgScalers-run122-06h13.jpg
Even with a more centered beam profile, AGATA request triggers is increasing too much and too fast!!! after 5 mn run, we are already at 100khz!!! 

Need Bertrand to solve the situation. 
Fixed, e768s, Mon Jul 22 06:32:40 2019, Faïrouz & Sylvain, RUN, General, LiF, We put the Faraday cup because AGATA can not cope with the very high counting rate (>110kHz) 
We will call Emmanuel & Bertrand. 
We stopped the run 122, waiting for Bertrand to come and work on the beam size and focalization. 
Fixed, e768s, Mon Jul 22 07:48:03 2019, OttoRun, RUN, General, LiF, Run123 
*************************
  [SIZE=3][B]Run  : 123[/B][/SIZE]
*************************
Fixed, e768s, Mon Jul 22 08:23:02 2019, Christian - Bertrand, Sylvain, Frank, Francois, BEAM, General, LiF, Beam adjustment notes 26C24EB9-097B-4078-8E8F-95BB07B0847A.jpeg
Adjustment of beam position, moved up by approximately 15mm on VAMOS FP, down by 2mm on target. AGATA rate reduced to normal, about 4k after 5 min equilibration,
no substantial satellite seen in direct beam on VAMOS FP. See separate entry for detailed discussion. Note, however that while beam intensity measurement
is 2.1e7, VAMOS trigger on reaction setting is approximately 1100. 
Fixed, e768s, Mon Jul 22 08:26:07 2019, OttoRun, RUN, General, LiF, Run124 
*************************
  [SIZE=3][B]Run  : 124[/B][/SIZE]
*************************
Fixed, e768s, Mon Jul 22 08:28:00 2019, mugast, OTHER, General, LiF, Scalers at start of run124 scalers_run124_0.png
 
Fixed, e768s, Mon Jul 22 08:29:19 2019, Faïrouz, Sylvain, Francois et Franck, Bertrand, BEAM, General, LiF, Beam profile updated index.jpgscalers_run124_0.png
To solve the very high counting rate observed on AGATA (and on MUST2 with a lesser degree), the beam was retuned. 

After inspection of the beam profile in VAMOS, Bertrand tuned the vertical steerers G1.DC21-VE (from 0.5 -> 0.0A). The consequence is a shift of 2mm in
Fixed, e768s, Mon Jul 22 09:40:06 2019, Franck, François, Adrien, Jérémy, Nicolas, ONLINE, General, LiF, Screenshots run 124 22x
 
Fixed, e768s, Mon Jul 22 10:01:12 2019, Franck, François D, BEAM, General, LiF, Beam profile IMG_20190722_095235.jpg
Slight shift in vertical +1 mm (with respect to this morning at 8:30)?

Intensity = 1.7e7 pps
    Fixed, e768s, Mon Jul 22 10:10:02 2019, Christian, OTHER, General, , Previous Papers - alpha-branching ratios for states in the 4-MeV region Phys.Rev.Lett._2007_Tan.pdfPhys.Rev.C_2008_Mythili.pdfScreen_Shot_2019-07-22_at_10.24.24.pngScreen_Shot_2019-07-22_at_10.43.17.png

Branching ratio data overview from Tan et al. (PRL 2007, attached):
Ex/MeV      B_alpha
Fixed, e768s, Mon Jul 22 11:16:09 2019, OttoRun, RUN, General, LiF, Run125 
*************************
  [SIZE=3][B]Run  : 125[/B][/SIZE]
*************************
Fixed, e768s, Mon Jul 22 11:42:22 2019, Marlène, François D, Franck, BEAM, General, LiF, Beam profile and intensity IMG_20190722_113900.jpg
Intensity = 1.8e7 pps

Slight shifts in x and y compared to this morning 8:30
Fixed, , Mon Jul 22 12:33:17 2019, Kseniia, AGATA, General, , Stats on 19Ne runs112-124-ebe.pngrun112-124-ebe.pngbeta19Ne.png
Full stats for runs 112..124 with the event-by-event Doppler correction. So, we see 4140 kev.
Also, the betas of all the 19Ne with Q= 9,10 identified in VAMOS
Fixed, , Mon Jul 22 12:54:25 2019, Kseniia, AGATA, General, , Beta vs gamma-ray energy in 19Ne, runs 112-124 betaVSgamma.png
 
Fixed, e768s, Mon Jul 22 13:40:41 2019, Franck, ONLINE, General, LiF, Run 125 screenshots 22x
 
Fixed, e768s, Mon Jul 22 14:45:34 2019, François D, Franck, BEAM, General, LiF, Beam profile Beam_profile_run125_22July2019_14h39.jpg
Intensity = 1.3e7 pps

Beam position shift compared to this morning 8:30
Fixed, e768s, Mon Jul 22 15:27:35 2019, Freddy, Valerian, Adrien, OFFLINE, General, LiF, Ex-Egamma ExGamma_run115-121.pngExEgamma_r112_121_kine.png
Ex Egamma for run 112 115 116 117 118 119 120 121.
Fixed, e768s, Mon Jul 22 16:08:24 2019, OttoRun, RUN, General, LiF, Run126 IMG_20190722_160212_beamcheck.jpgscalers_run126_0.png
*************************
  [SIZE=3][B]Run  : 126[/B][/SIZE]
*************************