Fixed, e768s, Sat Jul 20 12:57:41 2019, Christian, OTHER, General, , Previous Papers - gamma decays from states in the 4-MeV region
|
2019 paper by Hall, Bardayan, et al., gamma decays of 4.14 and 4.20 states, g-g-t triple coincidences.
Abstract:
|
Fixed, e768s, Sat Jul 20 14:00:22 2019, OttoRun, RUN, General, LiF, Run117
|
*************************
[SIZE=3][B]Run : 117[/B][/SIZE]
*************************
|
Fixed, e768s, Sat Jul 20 14:21:22 2019, Nikola, ONLINE, General, , screenshots run 117 @ 14h20 22x
|
|
Fixed, e768s, Sat Jul 20 14:32:18 2019, Nicolas, BEAM, General, LiF, Beam profile & intensity (run 117 @ 14h30)
|
Beam intensity: 1.4e7 pps
VAMOS: ~ 1200 |
Fixed, e768s, Sat Jul 20 17:00:19 2019, OttoRun, RUN, General, LiF, Run118
|
*************************
[SIZE=3][B]Run : 118[/B][/SIZE]
*************************
|
Fixed, e768s, Sat Jul 20 17:03:23 2019, mugast, RUN, General, LiF, Run 117 stopped
|
Run 117 stopped because VAMOS VXI went offline |
Fixed, e768s, Sat Jul 20 17:06:12 2019, mugast, RUN, General, LiF, Run 118 Scaler
|
Start run 118 |
Fixed, e768s, Sat Jul 20 19:12:58 2019, Faïrouz & Sylvain, RUN, General, LiF, Run 118 screenshots @ 19h14 20x
|
|
Fixed, e768s, Sat Jul 20 19:21:56 2019, Marlene, Nicolas, Christian, Fairouz, OFFLINE, General, , Trying to understand AGATA g-ray yields
|
goal: we want to check whether the yields of the 1297.7 keV (from 19Ne 1536, 3/2+, l=1 state) and 1340 keV (from 19Ne 1615, 3/2-, l=2 state) g-ray lines
is compatible with what we expect from x-sec calculations
|
Fixed, e768s, Sat Jul 20 19:23:37 2019, Christiqn, OFFLINE, General, LiF, Ex in 19F from run 72
|
[B]Data: Total integral for peak region around 4 MeV in 19F during run 72:
[/B]
|
Fixed, e768s, Sat Jul 20 19:24:31 2019, Faïrouz & Sylvain, RUN, General, LiF, Beam intensity is decreasing.
|
The beam intensity decreased by half since 19h00 (600 in Vamos-or)due to the primary beam.
The operators are working on it since.
The intensity of 10^7 pps came back at 8 pm.
|
Fixed, e768s, Sat Jul 20 21:10:57 2019, Faïrouz & Sylvain, RUN, General, LiF, Run 118 stopped because VXI Vamos turned offline because of overheat
|
Run 118 stopped because VXI Vamos turned offline of overheat |
Fixed, e768s, Sat Jul 20 23:18:02 2019, OttoRun, RUN, General, LiF, Run119
|
*************************
[SIZE=3][B]Run : 119[/B][/SIZE]
*************************
|
Fixed, e768s, Sat Jul 20 23:32:44 2019, Sylvain Fairouz, OFFLINE, General, , Trying to understand AGATA g-ray yields
|
[quote="Marlene, Nicolas, Christian, Fairouz"]goal: we want to check whether the yields of the 1297.7 keV (from 19Ne 1536, 3/2+, l=1 state) and 1340 keV
(from 19Ne 1615, 3/2-, l=2 state) g-ray lines is compatible with what we expect from x-sec calculations
|
Fixed, e768s, Sat Jul 20 23:43:02 2019, mugast, RUN, General, LiF, Run 119 (Problem with VXI fixed for the moment)
|
Run 119.
Or-Vamos= 1430 ---> I=1.43x10^7 pps |
Fixed, e768s, Sat Jul 20 23:57:34 2019, Diego, OFFLINE, General, , VAMOS acceptance, comparison between 9+ and 10+ states
|
Figures above, simulation of VAMOS acceptance for 10+ and 9+ 19Ne charge states. Ratio between them quite big (0.58)
Figures below, comparison of the states with offline data. Ratio much smaller.
It seems like acceptance doesn't cut the 10+ charge state too much, but 10+ is less produced than 9+. |
Fixed, e768s, Sun Jul 21 01:57:59 2019, Jenn & Franck, ONLINE, General, LiF, Screenshots run 119 21x
|
|
Fixed, e768s, Sun Jul 21 04:48:52 2019, Jenn & Franck, BEAM, General, N/A, Beam intensity check
|
OR Vamos: 1300 /s
Vamos gas profiler: 1.7x10^7 pps |
Fixed, e768s, Sun Jul 21 09:10:50 2019, Didier & Nicolas, BEAM, General, N/A, Beam intensity check
|
[quote="Jenn & Franck"]OR Vamos: 1300 /s
Vamos gas profiler: 1.7x10^7 pps[/quote]
|
Fixed, e768s, Sun Jul 21 10:58:39 2019, Christian, AGATA, General, LiF, 13c resync
|
13c resync at 10.57
lost 5 min agata data |
|