Fixed, e768s, Fri Jul 19 16:43:08 2019, OttoRun, RUN, General, LiF, Run116
|
*************************
Run : 116
*************************
Start at 2019-07-19 16:42:58.163547
Stop at 2019-07-20 04:34:58.716855
Stop comment: type your message here
Stop at 2019-07-20 10:40:22.875934
Stop comment: loss beam, premary beam monitor |
Fixed, e768s, Fri Jul 19 17:15:46 2019, mugast, RUN, General, LiF, Run 116
|
|
Fixed, e768s, Fri Jul 19 17:33:21 2019, Nicolas, OTHER, General, , AGATA: what if a crystal status get red
|
1. Go to the AGATA Digitizer: Control tab of the browser
2. Select the detector and crystal, then click 'Select'
3. Click the 'ReSync Current Digitizer Optical Link'
Normally it should go green again, otherwise call AGATA people |
Fixed, e768s, Fri Jul 19 17:52:24 2019, Nicolas, OTHER, General, , AGATA: replaying runs
|
1. Go to the AGATA analysis computer, open a terminal and execute the following commands:
> a4
> t e768s
> cd Replay
> ./do_global_replay.sh -run ### (### is the run number you want to convert)
if it complains that the folder with the run already exists, just > rm -rf runXXXX/ (where XXXX is the run you're replaying) in the Replay folder
2. When it is finished copy the root file to the GANIL world:
> mkdir /dataganil/e768s/acquisition/root_agata/run_0###
> cp ./run_0###/Out/Analysis/Tree_00*.root /dataganil/e768s/acquisition/run_0### |
Fixed, e768s, Fri Jul 19 18:57:12 2019, mugast, ONLINE, General, LiF, screenshots run 116 17x
|
|
Fixed, e768s, Fri Jul 19 21:43:35 2019, Franck & Faïrouz, RUN, General, LiF, screenshots run 116 @ 21h30 17x
|
|
Fixed, e768s, Fri Jul 19 22:16:43 2019, mugast, ONLINE, General, N/A, How to restart the vamos spectrum visualization (on the mugast daq computer)
|
On the mugast DAQ computer:
* Open a terminal
* Type "GoToVamosAna"
* Type "vigru"
* In vigru: File, Open config -> vigru_ganp154.xml
* Then: Setup, Sources, Host/FileName: "ganp154", port:9090
If a spectrum is missing -> Add it with "display one histo" |
Fixed, e768s, Fri Jul 19 23:10:18 2019, Franco, RUN, General, 3-alpha, Run302
|
Added energy calibration for square detector (MG 10).
OttoRun wrote: | *************************
Run : 302
*************************
Start at 2019-07-11 16:54:22.512184
3 alpha calibration run
+ without MM2 masks
+ suppressed pedestals
Square detectors:
+ MG10: all X strips masked; mate 14 & 16 masked
+ MG9: all X & Y strips masked
Stop at 2019-07-12 05:44:35.805449
Stop comment: |
|
Fixed, e768s, Fri Jul 19 23:12:36 2019, Franco, RUN, General, 3-alpha, Run302
|
Added energy calibration for square detector (MG 10).
Franco wrote: | Attached the calibrated spectra for MUST2 and Mugast for run 302 (no pedestals).
OttoRun wrote: | *************************
Run : 302
*************************
Start at 2019-07-11 16:54:22.512184
3 alpha calibration run
+ without MM2 masks
+ suppressed pedestals
Square detectors:
+ MG10: all X strips masked; mate 14 & 16 masked
+ MG9: all X & Y strips masked
Stop at 2019-07-12 05:44:35.805449
Stop comment: |
|
|
Fixed, e768s, Sat Jul 20 00:01:27 2019, Franck & Faïrouz, RUN, General, LiF, screenshots run 116 @ 00h00 19x
|
Algeria won Africa nations cup!!!  |
Fixed, e768s, Sat Jul 20 01:02:10 2019, Serge & Franco, OTHER, General, , Night shift beam & resync
|
timeline of run 116
00:xx resync Agata #13C
00:57 lost beam, back at full intensity at 01:12
01:30 lost beam, back at full intensity at 01:45
01:37 FP_CATS5 tripped, reset
01:43 resync Agata #13C
02:04 resync Agata #13C
02:20 lost beam, back at full intensity at 02:30
02:36 resync Agata #13C
03:45 Vamos rate down to 900 pps, checked that intensity on profiler is 1.1e7 so decided to continue
05:58 resync Agata #13C
06:55 Vamos rate at 1400 pps but diamond is decreasing since several hours: we had 17500 counts at midnight and now only 7500.
Checked beam rate on profiler and found 1.8e7 so indeed it is the diamond efficiency that is going down steeply |
Fixed, e768s, Sat Jul 20 04:30:42 2019, Serge & Franco, RUN, General, LiF, screenshots run 116 @ 02h00 14x
|
|
Fixed, e768s, Sat Jul 20 04:47:49 2019, Serge & Franco, RUN, General, LiF, screenshots run 116 @ 04h30 15x
|
The rate in the diamond was decreasing even if the rate in VAMOS was more or less constant. Now it seems stabilized. |
Fixed, e768s, Sat Jul 20 05:58:18 2019, Franco, OFFLINE, General, , Time calibration for MG10_X 
|
Attached a tentative time calibration for the square MG10_X from run 89 (to be checked!).
Even applying the calibration the spectrum E_TOF for MG10 (run 115) displays many structures. |
Fixed, e768s, Sat Jul 20 08:01:06 2019, Nikola, ONLINE, General, , screenshots run 116 @ 08h00 22x
|
|
Fixed, e768s, Sat Jul 20 09:20:35 2019, Nikola, ONLINE, General, , screenshots run 116 @ 09h20 22x
|
|
Ongoing, , Sat Jul 20 09:32:02 2019, Kseniia, Christian, Nikola,, OTHER, General, , summary of the morning shift
|
timeline of run 116
09:15 resync AGATA crustal 13C, AGATA was in back-preassure for ~7 min
10:30 resync AGATA crustal 13C, AGATA was in back-preassure for ~3 min
10:40 run 116 stopped (PCP called, they have a problem with primary beam high intensity reader, they called in the on-call people) |
Fixed, e768s, Sat Jul 20 10:50:01 2019, Nikola, ONLINE, General, , End of run 116 (beam problem) -> screenshots run 116 end @ 10h40 22x
|
1. A monitor of the primary beam failed and the astreinte had to be call (PCP did it).
2. The H2O cold box went in default. The cold water for AGATA digitizer; vamos crates and CTA went up to 25 deg!
Reset..... waiting that it goes back to 17deg in the cave circuit |
Fixed, e768s, Sat Jul 20 11:33:01 2019, Christian, OTHER, General, , Previous Papers - gamma decays from states in the 4-MeV region
|
This search was triggered by our lack of seeing the 3958keV line at the expected level. 2689 keV line observed (runs 112,115,116) as 55-60 counts. Expected yield in 3958 keV line based on 80:20 branching and 1.5:1.0 efficiency is 10 counts. We see (at most) 2 in the full photo-peak for this line. (Theses two counts are also lower than expected by about 20 keV.)
The 4.20 MeV to 0.24MeV line in the attached spectrum (p. 2 of J.M.Davidson & M.L.Roush) is one of three spectra by them, on which this branching ratio was based. With the level of detail in these spectra, I think it is fair to question this result. NNDC and TUNL data for branching ratios of this state is entirely based on this paper.
Action: other branching ratios in this region should be checked in this paper to see whether there could be other dubious branchings. |
Fixed, e768s, Sat Jul 20 12:06:00 2019, Christian, OTHER, General, , Previous Papers - gamma decays from states in the 4-MeV region
|
Further to the previous post on gamma-ray lines, attached is Kanungo's paper on doppler-attenuation measurement of the 4033 line for lifetime measurement. The lower-energy lines are, however, not included in the figures. |
|