Fixed, e768s, Fri Jul 19 16:43:08 2019, OttoRun, RUN, General, LiF, Run116
|
*************************
[SIZE=3][B]Run : 116[/B][/SIZE]
*************************
|
Fixed, e768s, Fri Jul 19 17:15:46 2019, mugast, RUN, General, LiF, Run 116
|
|
Fixed, e768s, Fri Jul 19 17:33:21 2019, Nicolas, OTHER, General, , AGATA: what if a crystal status get red
|
1. Go to the AGATA Digitizer: Control tab of the browser
2. Select the detector and crystal, then click 'Select'
3. Click the 'ReSync Current Digitizer Optical Link'
|
Fixed, e768s, Fri Jul 19 17:52:24 2019, Nicolas, OTHER, General, , AGATA: replaying runs
|
1. Go to the AGATA analysis computer, open a terminal and execute the following commands:
> a4
> t e768s
|
Fixed, e768s, Fri Jul 19 18:57:12 2019, mugast, ONLINE, General, LiF, screenshots run 116 17x
|
|
Fixed, e768s, Fri Jul 19 21:43:35 2019, Franck & Faïrouz, RUN, General, LiF, screenshots run 116 @ 21h30 17x
|
|
Fixed, e768s, Fri Jul 19 22:16:43 2019, mugast, ONLINE, General, N/A, How to restart the vamos spectrum visualization (on the mugast daq computer)
|
On the mugast DAQ computer:
* Open a terminal
|
Fixed, e768s, Fri Jul 19 23:10:18 2019, Franco, RUN, General, 3-alpha, Run302
|
Added energy calibration for square detector (MG 10).
[quote="OttoRun"]*************************
|
Fixed, e768s, Fri Jul 19 23:12:36 2019, Franco, RUN, General, 3-alpha, Run302
|
Added energy calibration for square detector (MG 10).
[quote="Franco"]Attached the calibrated spectra for MUST2 and Mugast for run 302 (no pedestals).
|
Fixed, e768s, Sat Jul 20 00:01:27 2019, Franck & Faïrouz, RUN, General, LiF, screenshots run 116 @ 00h00 19x
|
Algeria won Africa nations cup!!! :-)) |
Fixed, e768s, Sat Jul 20 01:02:10 2019, Serge & Franco, OTHER, General, , Night shift beam & resync
|
timeline of run 116
00:xx resync Agata #13C
|
Fixed, e768s, Sat Jul 20 04:30:42 2019, Serge & Franco, RUN, General, LiF, screenshots run 116 @ 02h00 14x
|
|
Fixed, e768s, Sat Jul 20 04:47:49 2019, Serge & Franco, RUN, General, LiF, screenshots run 116 @ 04h30 15x
|
The rate in the diamond was decreasing even if the rate in VAMOS was more or less constant. Now it seems stabilized. |
Fixed, e768s, Sat Jul 20 05:58:18 2019, Franco, OFFLINE, General, , Time calibration for MG10_X 
|
Attached a tentative time calibration for the square MG10_X from run 89 (to be checked!).
Even applying the calibration the spectrum E_TOF for MG10 (run 115) displays many structures. |
Fixed, e768s, Sat Jul 20 08:01:06 2019, Nikola, ONLINE, General, , screenshots run 116 @ 08h00 22x
|
|
Fixed, e768s, Sat Jul 20 09:20:35 2019, Nikola, ONLINE, General, , screenshots run 116 @ 09h20 22x
|
|
Ongoing, , Sat Jul 20 09:32:02 2019, Kseniia, Christian, Nikola,, OTHER, General, , summary of the morning shift
|
timeline of run 116
09:15 resync AGATA crustal 13C, AGATA was in back-preassure for ~7 min
|
Fixed, e768s, Sat Jul 20 10:50:01 2019, Nikola, ONLINE, General, , End of run 116 (beam problem) -> screenshots run 116 end @ 10h40 22x
|
1. A monitor of the primary beam failed and the astreinte had to be call (PCP did it).
2. The H2O cold box went in default. The cold water for AGATA digitizer; vamos crates and CTA went up to 25 deg!
|
Fixed, e768s, Sat Jul 20 11:33:01 2019, Christian, OTHER, General, , Previous Papers - gamma decays from states in the 4-MeV region
|
This search was triggered by our lack of seeing the 3958keV line at the expected level. 2689 keV line observed (runs 112,115,116) as 55-60 counts. Expected
yield in 3958 keV line based on 80:20 branching and 1.5:1.0 efficiency is 10 counts. We see (at most) 2 in the full photo-peak for this line. (Theses two
counts are also lower than expected by about 20 keV.)
|
Fixed, e768s, Sat Jul 20 12:06:00 2019, Christian, OTHER, General, , Previous Papers - gamma decays from states in the 4-MeV region
|
Further to the previous post on gamma-ray lines, attached is Kanungo's paper on doppler-attenuation measurement of the 4033 line for lifetime measurement.
The lower-energy lines are, however, not included in the figures. |
|