MUST2
SAMURAI_2018
S3-LEB-LPC
SUPERNEMO
MUGAST
EXPAND
SCALP
GALATRON
HiCARI
VELO
MUGAST, Page 101 of 132
Not logged in
Find
|
Login
Full
| Summary |
Threaded
2636 Entries
Goto page
Previous
1
,
2
,
3
...
100
, 101,
102
...
130
,
131
,
132
Next
Status
ExpNbr
Date
Author
Type
Category
Target-Source
Subject
Text
Fixed
e768s
Fri Jul 19 16:43:08 2019
OttoRun
RUN
General
LiF
Run116
*************************
[SIZE=3][B]Run : 116[/B][/SIZE]
*************************
Fixed
e768s
Fri Jul 19 17:15:46 2019
mugast
RUN
General
LiF
Run 116
Fixed
e768s
Fri Jul 19 17:33:21 2019
Nicolas
OTHER
General
AGATA: what if a crystal status get red
1. Go to the AGATA Digitizer: Control tab
of the browser
2. Select the detector and crystal, then
Fixed
e768s
Fri Jul 19 17:52:24 2019
Nicolas
OTHER
General
AGATA: replaying runs
1. Go to the AGATA analysis computer, open
a terminal and execute the following commands:
> a4
Fixed
e768s
Fri Jul 19 18:57:12 2019
mugast
ONLINE
General
LiF
screenshots run 116
17x
Fixed
e768s
Fri Jul 19 21:43:35 2019
Franck & Faïrouz
RUN
General
LiF
screenshots run 116 @ 21h30
17x
Fixed
e768s
Fri Jul 19 22:16:43 2019
mugast
ONLINE
General
N/A
How to restart the vamos spectrum visualization (on the mugast daq computer)
On the mugast DAQ computer:
* Open a terminal
Fixed
e768s
Fri Jul 19 23:10:18 2019
Franco
RUN
General
3-alpha
Run302
Added energy calibration for square detector
(MG 10).
Fixed
e768s
Fri Jul 19 23:12:36 2019
Franco
RUN
General
3-alpha
Run302
Added energy calibration for square detector
(MG 10).
Fixed
e768s
Sat Jul 20 00:01:27 2019
Franck & Faïrouz
RUN
General
LiF
screenshots run 116 @ 00h00
Algeria won Africa nations cup!!! :-))
19x
Fixed
e768s
Sat Jul 20 01:02:10 2019
Serge & Franco
OTHER
General
Night shift beam & resync
timeline of run 116
00:xx resync Agata #13C
Fixed
e768s
Sat Jul 20 04:30:42 2019
Serge & Franco
RUN
General
LiF
screenshots run 116 @ 02h00
14x
Fixed
e768s
Sat Jul 20 04:47:49 2019
Serge & Franco
RUN
General
LiF
screenshots run 116 @ 04h30
The rate in the diamond was decreasing even
if the rate in VAMOS was more or less constant.
Now it seems stabilized.
15x
Fixed
e768s
Sat Jul 20 05:58:18 2019
Franco
OFFLINE
General
Time calibration for MG10_X
Attached a tentative time calibration for
the square MG10_X from run 89 (to be checked!).
Even applying the calibration the spectrum
Fixed
e768s
Sat Jul 20 08:01:06 2019
Nikola
ONLINE
General
screenshots run 116 @ 08h00
22x
Fixed
e768s
Sat Jul 20 09:20:35 2019
Nikola
ONLINE
General
screenshots run 116 @ 09h20
22x
Ongoing
Sat Jul 20 09:32:02 2019
Kseniia, Christian, Nikola,
OTHER
General
summary of the morning shift
timeline of run 116
09:15 resync AGATA crustal 13C, AGATA was
Fixed
e768s
Sat Jul 20 10:50:01 2019
Nikola
ONLINE
General
End of run 116 (beam problem) -> screenshots run 116 end @ 10h40
1. A monitor of the primary beam failed and
the astreinte had to be call (PCP did it).
22x
Fixed
e768s
Sat Jul 20 11:33:01 2019
Christian
OTHER
General
Previous Papers - gamma decays from states in the 4-MeV region
This search was triggered by our lack of seeing
the 3958keV line at the expected level. 2689
keV line observed (runs 112,115,116) as 55-60
Fixed
e768s
Sat Jul 20 12:06:00 2019
Christian
OTHER
General
Previous Papers - gamma decays from states in the 4-MeV region
Further to the previous post on gamma-ray
lines, attached is Kanungo's paper on doppler-attenuation
measurement of the 4033 line for lifetime
Goto page
Previous
1
,
2
,
3
...
100
, 101,
102
...
130
,
131
,
132
Next
ELOG Home Page