Fixede768s Fri Jul 19 16:43:08 2019 OttoRunRUNGeneralLiFRun116*************************
  [SIZE=3][B]Run  : 116[/B][/SIZE]
*************************
  
Fixede768s Fri Jul 19 17:15:46 2019 mugastRUNGeneralLiFRun 116   run116-Scaler2.png 
Fixede768s Fri Jul 19 17:33:21 2019 NicolasOTHERGeneral AGATA: what if a crystal status get red1. Go to the AGATA Digitizer: Control tab
of the browser
2. Select the detector and crystal, then
  
Fixede768s Fri Jul 19 17:52:24 2019 NicolasOTHERGeneral AGATA: replaying runs1. Go to the AGATA analysis computer, open
a terminal and execute the following commands:
> a4
  
Fixede768s Fri Jul 19 18:57:12 2019 mugastONLINEGeneralLiFscreenshots run 116   17x 
Fixede768s Fri Jul 19 21:43:35 2019 Franck & FaïrouzRUNGeneralLiFscreenshots run 116 @ 21h30   17x 
Fixede768s Fri Jul 19 22:16:43 2019 mugastONLINEGeneralN/AHow to restart the vamos spectrum visualization (on the mugast daq computer)On the mugast DAQ computer:

* Open a terminal
  
Fixede768s Fri Jul 19 23:10:18 2019 FrancoRUNGeneral3-alphaRun302Added energy calibration for square detector
(MG 10).
 run302_MG_Ecal.png 
Fixede768s Fri Jul 19 23:12:36 2019 FrancoRUNGeneral3-alphaRun302Added energy calibration for square detector
(MG 10).
 run302_MG_Ecal.png 
Fixede768s Sat Jul 20 00:01:27 2019 Franck & FaïrouzRUNGeneralLiFscreenshots run 116 @ 00h00Algeria won Africa nations cup!!! :-))  19x 
Fixede768s Sat Jul 20 01:02:10 2019 Serge & FrancoOTHERGeneral Night shift beam & resync timeline of run 116

00:xx resync Agata #13C
  
Fixede768s Sat Jul 20 04:30:42 2019 Serge & FrancoRUNGeneralLiFscreenshots run 116 @ 02h00   14x 
Fixede768s Sat Jul 20 04:47:49 2019 Serge & FrancoRUNGeneralLiFscreenshots run 116 @ 04h30The rate in the diamond was decreasing even
if the rate in VAMOS was more or less constant.
Now it seems stabilized.
 15x 
Fixede768s Sat Jul 20 05:58:18 2019 FrancoOFFLINEGeneral Time calibration for MG10_XAttached a tentative time calibration for
the square MG10_X from run 89 (to be checked!).
Even applying the calibration the spectrum
 run_0089_MG10_timecal.pngETOF_MG10_run115.png 
Fixede768s Sat Jul 20 08:01:06 2019 NikolaONLINEGeneral screenshots run 116 @ 08h00   22x 
Fixede768s Sat Jul 20 09:20:35 2019 NikolaONLINEGeneral screenshots run 116 @ 09h20   22x 
Ongoing  Sat Jul 20 09:32:02 2019 Kseniia, Christian, Nikola,OTHERGeneral summary of the morning shifttimeline of run 116

09:15 resync AGATA crustal 13C, AGATA was
  
Fixede768s Sat Jul 20 10:50:01 2019 NikolaONLINEGeneral End of run 116 (beam problem) -> screenshots run 116 end @ 10h401. A monitor of the primary beam failed and
the astreinte had to be call (PCP did it).
 22x 
Fixede768s Sat Jul 20 11:33:01 2019 ChristianOTHERGeneral Previous Papers - gamma decays from states in the 4-MeV regionThis search was triggered by our lack of seeing
the 3958keV line at the expected level. 2689
keV line observed (runs 112,115,116) as 55-60
 1-s2.0-0375947473901541-main.pdf 
Fixede768s Sat Jul 20 12:06:00 2019 ChristianOTHERGeneral Previous Papers - gamma decays from states in the 4-MeV regionFurther to the previous post on gamma-ray
lines, attached is Kanungo's paper on doppler-attenuation
measurement of the 4033 line for lifetime
 Phys.Rev.C_2006_Kanungo.pdf 