MUST2
SAMURAI_2018
S3-LEB-LPC
SUPERNEMO
MUGAST
EXPAND
SCALP
GALATRON
HiCARI
VELO
|
| MUGAST |
Not logged in |
|
|
|
Message ID: 5338
Entry time: Fri Jul 26 05:57:04 2019
|
| Author: |
Kseniia, Franck |
| ExpNbr: |
e768s |
| Type: |
ONLINE |
| Category: |
General |
| Status: |
Fixed |
| Target-Source: |
LiF |
| Subject: |
Run 149 screenshots |
|
|
A second beam component is visible in particular in IC energy losses (with Z larger than 7) and in MW.
This probably corresponds to the 15O from the Spiral target-ion source being warmed up by the primary beam that has increased overnight (~1200 W at 5:45 am).
Checked by reducing the primary intensity for a few minutes: the second component decreased to a level comparable to that at the beginning of run 149. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|