MUST2 SAMURAI_2018 S3-LEB-LPC SUPERNEMO MUGAST EXPAND SCALP GALATRON HiCARI VELO
  MUGAST  Not logged in MUGAST
Entry  Mon Jul 22 16:54:33 2019, Marlène, Franck, François & Nicolas, e768s, BEAM, General, Fixed, , Cheking beam transmission from G1 profiler to VAMOS 
    Reply  Tue Jul 23 14:33:03 2019, Marlène, Yorick, Faïrouz & Nicolas, e768s, BEAM, General, Fixed, , Cheking beam transmission from G1 profiler to VAMOS 714D4921-2A75-44B7-AD8D-87048BDA17A8.jpeg6A77930D-8992-4118-B59C-DBAA37289533.jpeg3CD66D1D-D6E6-44B4-A15A-C947F048D2A0.jpeg
Message ID: 5287     Entry time: Tue Jul 23 14:33:03 2019     In reply to: 5264
Author: Marlène, Yorick, Faïrouz & Nicolas 
ExpNbr: e768s 
Type: BEAM 
Category: General 
Status: Fixed 
Target-Source:  
Subject: Cheking beam transmission from G1 profiler to VAMOS 
Goal:
Estimate beam transmission from profiler to VAMOS (FP)
We question whether the factor of two found yesterday (VAMOS/Profiler ~ 0.5) could be due:
1. to an incorrect measurement of the beam intensity with the profiler
2. a charge state equilibration in the target (LISE++ calculation indicates 8+/7+ = 85%/15%)

Same conditions as yesterday:
1. Beam intensity is reduced with the pepper pot 1/9 and by closing slits after the 15O target production and the accelerators so that the beam quality (emittance, etc...) is not affected.
2. VAMOS plate is removed to allow the direct beam detection

Results:
We measure in VAMOS with the LiF target and with the target ladder totally removed. In the latter case, direct beam 15O(8+) is sent in VAMOS and no charge state effect enter into the game.
1. Beam intensity at G1 profiler ~ 6.5e4 pps
VAMOS (FP) + no target ~ 3.8e4 pps
2. Beam intensity at G1 profiler ~ 3.8e4 pps
VAMOS (FP) + thick LiF (nb 1) ~ 2.0e4 pps

Discussion:
We find the same results as yesterday, e.g. a factor of two attenuation between the profiler and VAMOS. If part of this loss would happen in the pipe/target/MUST2 mask, this should be observed in AGATA which is not the case. Could it be that the PPAC in VAMOS is not as efficient as announced at the beginning of the campaign (98%)? This must be checked when we get beam back later on.

Note:
While doing the above measurement, we observed a factor of 3 loss between profiler AR.Gaz13 and G1.Gaz31. Numbers follows:
L3.GAZ42 AR.GAZ13 G1.GAZ31
2.1e4 1.5e4 4.1e3
1.4e5 1.0e5 2.5e4
??? 1.8e5 6.5e4
Attachment 1: 714D4921-2A75-44B7-AD8D-87048BDA17A8.jpeg  2.117 MB  Uploaded Tue Jul 23 16:55:58 2019  | Hide | Hide all | Show all
714D4921-2A75-44B7-AD8D-87048BDA17A8.jpeg
Attachment 2: 6A77930D-8992-4118-B59C-DBAA37289533.jpeg  1.970 MB  Uploaded Tue Jul 23 16:56:13 2019  | Show | Hide all | Show all
Attachment 3: 3CD66D1D-D6E6-44B4-A15A-C947F048D2A0.jpeg  2.039 MB  Uploaded Tue Jul 23 16:56:28 2019  | Hide | Hide all | Show all
3CD66D1D-D6E6-44B4-A15A-C947F048D2A0.jpeg