MUST2 SAMURAI_2018 S3-LEB-LPC SUPERNEMO MUGAST EXPAND SCALP GALATRON HiCARI VELO
  MUGAST  Not logged in MUGAST
This is a draft message, edit and submit it to make it permanent  
Message ID: 5266     Entry time: Mon Jul 22 17:54:49 2019
Author: Christian and Jeremie 
ExpNbr: e768s 
Type: AGATA 
Category: General 
Status: Fixed 
Target-Source: LiF 
Subject: Comparison EGamma 19Ne, Q8 vs Q9 
1) Beam velocity from VAMOS for AGATA doppler correction. Beta is understandable for the three main charge states seen (with Q9 and Q10 as the transfer states, and centroid shifted higher for Q10 state, possibly because of reduced acceptance for the very high-lying states.

2) Entire doppler corrected gamma-ray spectrum. Blue is transfer (Q9), red is fusion evaporation (Q8). 1880 keV line only seen in fusion evaporation as expected, 13/2+ state.

3) Zoom at the region around 2.5 MeV. Note that
Attachment 1: 15.png  34 kB  Uploaded Mon Jul 22 18:56:04 2019  | Hide | Hide all | Show all
15.png
Attachment 2: 59.png  56 kB  Uploaded Mon Jul 22 18:56:10 2019  | Show | Hide all | Show all
Attachment 3: 27.png  29 kB  Uploaded Mon Jul 22 18:56:13 2019  | Hide | Hide all | Show all
27.png

ELOG Home Page