Author: Franco 
ExpNbr: e786s 
Type: RUN 
Category: General 
Status: Fixed 
Target-Source: Cryo-3He 
Subject: Run58 

OttoRun wrote:

OttoRun wrote:
*************************
Run : 58
*************************

Start at 2019-06-25 16:56:44.425517

target 700mb
Brho0=0.95 Tm
DC pressure 6 mbar
IC pressure 120 mbar
CATS2 inserted

AGATA position +51-25 mm

TRIGGER :
- VAMOS %1000
- CMG
- MM
- CATS2 %1000

Beam is back
scaler_run_58.png taken at the beginning of the run.


In the CATS position spectra the central part is missing (maybe for the high intensity of the beam?).
We can anyway recover the time information.

After the decrease of the high voltage of VAMOS drift chamber to avoid saturation of the signals
the BRho resolution has worsened of about 25% (see attachment). We will now increase it again (h. 22.30).