MUST2
SAMURAI_2018
S3-LEB-LPC
SUPERNEMO
MUGAST
EXPAND
SCALP
GALATRON
HiCARI
VELO
|
| MUGAST |
Not logged in |
|
|
Thu Apr 11 05:03:13 2019, Marlène, , RUN, Hardware, Fixed, CH2, TO DO list
|
Thu Apr 11 06:48:23 2019, iulian, e744s, RUN, Hardware, Fixed, CH2, TO DO list
|
|
|
Message ID: 3978
Entry time: Thu Apr 11 06:48:23 2019
In reply to: 3973
|
| Author: |
iulian |
| ExpNbr: |
e744s |
| Type: |
RUN |
| Category: |
Hardware |
| Status: |
Fixed |
| Target-Source: |
CH2 |
| Subject: |
TO DO list |
|
|
| mugast wrote: | - 2 TACS are not working:
- T_Si_CATS1 (stop should be CATS n FAG --> to be checked). Also Ok now. Same problem as below
- T_Si_VAMOS (seen now in T_CATS1_CATS2) --> check the signals (if CATS is the START we should use CATS n FAG, if it is the stop it should be delayed by 800 ns , the delay is prepared)
The was a broken Cable from the delay to fan in fan out.
Still remains T_Vamos_Cats1 with no counts. I suspect the necesity to put a 2 us delay on Cats1, or to inverse it and pout Cats1 fag validated as start
|
|
|